The difference and usage of three drying oven

图片
The difference of control panel between GX, DHG and KH series drying oven 1. Constant temperature drying oven GX, DHG, KH series, with LCD screen and digital display screen, adopts microcomputer intelligent PID technology, in which the temperature control accuracy of the LCD screen is ± 0.1 degrees, with RS485 microcomputer interface function, it can realize network management and monitoring, etc. The controllable accuracy of digital display meter is ± 0.5 degree. The accuracy and function of liquid crystal meter are obviously better than that of digital display instrument. 2. How to set the temperature and timing of the drying oven instrument: First, press the EST setting key, SP set temperature appears, press save, Se set time appears, press save, time is set to 0, which means timing. 3. Our oven has an over-temperature alarm function. If it exceeds the temperature, the instrument will beep. If you need sound and light alarm, you can install a sound and light alarm system. In orde

Video teaching: How to operate a constant temperature drying oven

图片
  Thermostatic Drying Oven: http://en.kentonchina.com/list/hot-air-oven.html

How to choose the volume of the constant temperature and humidity oven?

图片
For the constant temperature and humidity oven volume selection, many people do not know what big volume they should buy, in fact, in order to ensure that the product around the atmosphere can meet the test specification within the environmental test conditions, the selected volume should pay attention to several points. 1. the volume of the test product shall not exceed 20% -35% of the chamber (studio) space, more than 35% is likely to affect the effectiveness of the test. 2. (2) For the product that generates heat in the experiment, it should not exceed 10%. 3 test product windward cross-sectional area and the cross-section of the constant temperature and humidity oven studio area than 35% -50%. The above points of attention are and airflow, environment, and degree of two factors that are closely related do not save money and choose a volume that is not suitable for the constant temperature and humidity oven . Kenton technology manufacturers, professional production constant tempera

Comparison and introduction of material structure of several seris heating incubators

图片
 As a powerful manufacturer in China, several constant temperature incubators are popular in the market. So what are the characteristics of these incubators in terms of material structure? PX series incubator is made of high-quality cold-rolled steel plate with environmental protection electrostatic spraying, and the inner tank is made of SUS304 stainless steel, which is more suitable for the environmental requirements of acid-base and anti-corrosion of a scientific research laboratory. Advanced inner chamber preheating technology, the inner wall of the inner chamber is preheated by the three side ring stainless steel heating pipe, which makes the temperature rise faster and the temperature stability better (beat the inner tank). You can also choose the LCD screen, touch screen, segmented screen, temperature limiter, etc DNP series outer box is made of high-quality cold-rolled steel plate with environmental protection electrostatic spraying, and the inner tank is made of mirror 201 s

Does the laminar flow hood use an alcohol lamp?

图片
Some laboratory workers, often discuss a problem: alcohol lamp should be used or not in laminar flow hood ? There are many different views on this. positive side: First of all, the purified air in the laminar flow hood (super clean table) is blown from the top to the bottom, and its heat can form convection, which can form a sterile area locally to prevent microbial infection. Secondly, the disinfection effect of alcohol lamp can not be ignored: the generated high temperature can eliminate cells and avoid cross contamination of cells; disinfection of used straws in the ultra clean table is also necessary, because ultraviolet rays can not 100% eliminate microorganisms nagative side: In fact, the use of alcohol lamp will cause air convection, which will bring dust on the ultra clean table, but increase the chance of pollution. What's more, it also increases the risk of fire. In fact, there are reasons for the above discussion. The JH series laminar flow hood  of Kenton instrument has

How to use anaerobic incubator for cell anaerobic experiment?

图片
Do cell anaerobic experiment, need cell anaerobic culture to do a follow-up, had better use to the anaerobic incubator . Process: After the medium is prepared, it is separately packed in the screw mouth test tube, and the screw cap is released for high-pressure sterilization at 121 ℃ for 20 minutes. After sterilization, it is quickly put into the sampling chamber of the anaerobic incubator which has been inflated and replaced for one hour. After vacuuming and filling with nitrogen, the medium is taken into the operation room by opening the inner door (the main purpose is that the sterilization process of the medium is also dissolved out of it). Screw the screw cap tightly, and then carry out the corresponding dilution and mixing operation in the operating room. Then screw the lid tightly, take out the anaerobic tank, seal with sealing glue, and roll the test tube, and then culture at 55 ℃. Control table operation of the anaerobic incubator , Click the "set" key to enter into

What are the features of an Anaerobic incubator?

图片
  YQX-II anaerobic incubator is composed of a culture operation room, vacuum sampling room, gas circuit, circuit control system, etc. The whole machine is a novel, compact structure, with a good anaerobic environment, good sealing performance, high precision temperature control, good stability, convenient use, economical, safe, and reliable work. The whole machine is a novel, compact structure, with good anaerobic environment, good sealing performance, high precision temperature control, good stability, easy to use, gas-saving, economic, safe, and reliable work. Its features are as follows. 1 、 The use of scientific and advanced means to achieve an anaerobic environment, high precision, good stability, and reliable use. 2 、 Electrical heating fan circulation system is installed in the operating room, forming the overall structure of the operating room incubator, which can effectively enhance the operating space. 3 、 Temperature control system adopts a precision microcomputer intellige

Can I print data from a Humidity chamber?

图片
Usually, some customers will ask if the constant temperature and humidity chamber can print data. Kenton laboratory LRH constant temperature and humidity chamber is able to print data. Introduced as follows. 1. time window; displays the current time (hours . minutes) in the normal state. Minutes). 2.POWER indicator (power indicator): light indicates that the printer controller has been powered on. 3.OUT indicator (print output indicator): the light indicates that there is print output. 4.RS485 light (PC communication light): the light indicates that the current communication is PC, the printer is not available; the PC monitoring system is available. 5.PRT indicator (printer communication indicator): the light indicates that the printer is currently communicating and the printer is available. Unavailability of PC-based monitoring systems. 6. key (setting key): in a normal state, click to set the print interval; press and hold for 3 seconds to enter setting state; in setting state, cli

Introduction of anaerobic incubator

图片
 An anaerobic incubator is a special device for bacterial culture and operation in an anaerobic environment. It can provide strict anaerobic conditions, constant temperature culture conditions, and has a systematic, scientific working area. The operation of the culture in this device can cultivate all kinds of anaerobic organisms that need to grow in an anaerobic environment and avoid the risk of death of anaerobic organisms due to exposure to oxygen during operation in the atmosphere. Therefore, this device is an ideal special instrument for anaerobic biological detection institute and anaerobic biological research unit. This device is also a good multi-purpose instrument. If the operation mode is changed, the built-in oxygen detector (supplied by the user) can be adopted, and the flow adjustment device which is required and fitted to the operation panel can be passed. The specified oxygen content of microaerobic can satisfy the growth and reproduction of microaerobic and provide goo

The difference between the three drying ovens and how to use them

图片
 1. The difference between the control panel of the drying oven GX, DHG and KH series Constant temperature drying oven GX, DHG, KH series, divided into LCD screen and digital display screen, using microcomputer intelligent PID technology, the LCD screen temperature control accuracy is ±0.1 degrees, with RS485 microcomputer interface function, can realize network management and monitoring, etc. The controllable accuracy of the digital display meter is ±0.5 degrees. In terms of accuracy and function, the LCD meter is obviously better than the digital display meter. 2. Then about the setting method of the temperature and timing of the drying oven instrument: Press the Est setting key first, the SP setting temperature appears, click to save, and the SE setting time appears, click to save, and the time is set to 0, which means that it is irregular. 3. Our oven has an over-temperature alarm function. If the temperature exceeds the temperature, the instrument will buzz and alarm. If you nee

The difference between the control panels of the three incubators

图片
Kenton Laboratory has very many series of incubators, constant temperature incubators, biochemical incubators, mold incubators, constant temperature and humidity incubators, and so on. So what is the difference between several popular thermostatic incubators in the control panel? 303 thermostatic incubator DNP series thermostatic incubator PX series thermostatic incubator PX, DNP and 303 series of  thermostatic incubator  control panel difference (with three kinds of laboratory put a small picture in the upper left corner for instructions, LCD and digital display meter to be powered to display the picture before the effect), PX series standard with LCD screen, DNP series have LCD or digital display meter, 303 series with digital display meter or pointer meter. The LCD temperature control accuracy is ± 0.1 degrees, with RS485 microcomputer interface function, network management, and monitoring can be realized. The controllable accuracy of the digital display is ±0.5 degrees. Accuracy a

Common laboratory applications for incubators

图片
 Incubator applications are common in laboratories, and the lack of incubators in laboratories is somewhat meaningless. CO2 incubator : in vitriol culture of cells, like in viva culture, needs to be produced in a stable environment and is generally suitable for The growth temperature is over 20 degrees. If you need a Thermostatic incubator with precise temperature control, CO2 incubator and constant temperature and humidity incubator are the better choices. co2 incubator Thermostatic incubator : For general plant and insect culture, you can choose a water-separated or transistor type automatic temperature control incubator. Ordinary Thermostatic incubators can meet the requirements of cultivation, and the price is also relatively cheap. electric heating incubator Mold incubator: Mold incubator with ultraviolet sterilization function, suitable for the cultivation of mold and other eukaryotic microorganisms test equipment, because of Most molds are suitable for growth at room temperatur

Drug stability test chamber common trouble-shooting methods

图片
Drug stability test chamber is a scientific method to create a drug failure assessment of the required long-term stable temperature and humidity environment, suitable for pharmaceutical companies on drugs and new drugs accelerated tests, long-term experiments, high-temperature tests, and strong light irradiation test, is the best choice for pharmaceutical companies to carry out drug stability test. Common failures of the stability test chamber and how to deal with them. 1. Sensor failure alarm The temperature/humidity sensor is abnormal, check that the temperature/humidity sensor is intact and can be replaced if damaged. 1. Temperature not rising to set value Check whether the display shows the heating status, if it shows heating, the electric heating pipe is damaged or the control board or line is defective. 1. No light -Check that the light level setting is on. -Check that the illumination cycle has been completed. -If the above is normal, check the fault according to the wiring dia

The material comparison of different types of vacuum drying oven

图片
 The material comparison of different types of vacuum drying oven Product Comparison Presentation. 1.For the construction and material differences between the KZ, DZF   vacuum drying oven  models, described below.   The inner cavities of KZ and DZF-S series are made of SUS304 stainless steel, which is very suitable for research laboratories with acid and alkali resistant and corrosion resistant environments. Only the inner cavity of the DZF series without S is made of cold-rolled steel plate, which can be selected by users according to actual needs. The KZ series adopts the international advanced preheating technology of the inner cavity. The three-sided annular stainless steel heating tube preheats the inner wall of the inner cavity first, which makes the temperature rise faster and the temperature stability better (picture). The KZ-G high-match model is equipped with laminar heat transfer technology, which transfers the heat directly to the sample through the aluminum laminar, and so

What are the differences between different types of industrial ovens?

 What are the differences between different types of industrial ovens ? Material comparison of products introduced. 1 Regarding the distinction between.AS, A, and C for some users, the following is described. AS stands for stainless steel liner. The C series is sealed with asbestos rope, which is resistant to high temperature, and the A-series is sealed with silicone, which is not as good as silicone and has some pollution. As for the electrical components, the C series adopts domestic brand electrical fittings, and the A-series adopts joint venture Delisi brand electrical fittings. As for door handle, the C series adopts a snap-type door buckle, which can close the door only when pressed; A series adopts an adiabatic rotary type door buckle, which can adjust the sealing. As for door hinges, the C series adopts welded round hinges, which are strong in load-bearing but not easy to replace, while the A series adopts alloy door hinges, which are easy to replace and more durable. Customers

Product characteristics of industrial oven

图片
Product characteristics of industrial oven : Features of the product. This product is mainly used for dehydration, drying, such as electroplating, electronics industry, alloy jewelry coloring, plastic industry, leather industry, hardware, and other production industries, but not for strong volatile, flammable and explosive items, in order to avoid causing an explosion. 2. Suitable for industrial and mining enterprises and workshops for mass production can work for a long time. And has a large storage capacity, fast heating time, and other characteristics. 3. 3. standard with intelligent temperature control with PID self-adjustment and timing function, large-diameter wind wheel with circulating fan, so that more uniform heat circulation. Test according to the national standard requirements of the record liner 9 points of the average fluctuation within ± 2 degrees. 4. Can be customized according to customer requirements of different specifications of the size. There are front and r

Reasons for choosing Kenton (kenton high configuration brand)

图片
In the market, among the laboratory equipment, such as drying oven , incubator, test chamber, etc., the quotation of different manufacturers is quite different. When the same product is put in front of you and different configurations are available, the Kenton instrument will tell you how to choose. the reasons to choose Kenton high configuration, 1. Meet the high-end requirements of experimental equipment, representing the international advanced design, environmental protection concept. Ergonomic design, more convenient to use. Pay attention to safety design, protect scientific research workers and meet international safety standards 2. All key components are of international famous brands, with more guaranteed quality, longer warranty period and two-year global warranty 3. The housing is made of thickened material, and the inner tank is made of 304 stainless steel, which is more corrosion-resistant than ordinary stainless steel 4. Equipped with intelligent LCD instrument, stand

The drying oven is classified by temperature, how many are there generally?

图片
The drying ovens are classified by different factors, and the types have their own characteristics, and the drying ovens are distinguished by their rated temperatures, which can generally be divided into. Low-temperature drying oven: below 100℃, use: aging of electrical products, slow drying of common materials, drying of some food raw materials, plastic, and other products. constant temperature drying oven : 100-250℃, use: moisture drying of raw materials, curing of coating, heating, heating, heat preservation, and so on. High-temperature drying oven: 250-400℃, use: high-temperature drying of special materials, workpiece heating installation, high-temperature testing of materials, reaction treatment of chemical raw materials, etc. Ultra-high temperature drying oven: 400-600℃, use: high-temperature drying of special materials, workpiece heating heat treatment, the high-temperature test of materials, etc. After 20 years of drying oven technology accumulation, Kenton laboratory Co.