博文

目前显示的是 九月, 2021的博文

the temperature uniformity in the vacuum drying oven

图片
Kenton laboratory vacuum drying oven original inner cavity preheating technology and heat transfer technology of the partition plate, increase the contact area between the partition plate and the preheating cavity so that the temperature of the partition plate and the preheating cavity remain the same. the temperature uniformity in the vacuum drying oven 1, The number of the heating surfaces is an important reason to decide the temperature uniformity. The effect of heating on four sides is definitely much better than that of heating on two sides, and the temperature uniformity at various points inside the cavity is higher. 2, The partition comes with its own independent heating tube, which is heated inside the cavity and the heat is conducted through the laminate. This method can heat up quickly and the temperature is more uniform, the disadvantage is that it is slightly more expensive. 3, Part of the heat is conducted by the partition, so increasing the contact area between the partit

Tips for safe use of biochemical incubators

 In order to use the biochemical incubator more safely, the following points should be noted 1. If you need to use the device again after stopping for a long time, carefully check the water source, power supply, and all components, and then start the device after confirming no error. 2. In the test stage, the time of opening the chamber door should be reduced as much as possible. 3, the sensor device in the working room, does not suffer from strong impact. 4. During the operation of the equipment, adequate water must be maintained. 5. Non-full-time operators shall not operate at will. 6, the equipment can not troubleshoot their own, please contact the company. 7, because ultraviolet radiation to personnel (especially the eyes) has strong harm, so the operator should minimize exposure to ultraviolet light (contact time should be < 1min). It is recommended that operators wear protective goggles and jackets. Kenton instrument is a powerful manufacturer in China with a history of more

There are three ways to light the incubator

图片
Illumination incubator( light incubator ), on the market, there are three types of illumination: the first type is partition illumination, that is, the illumination device is located in the partition, and each layer of the partition with illumination can receive illumination evenly. The second kind of lighting is to bring lighting function to each layer of doors. The third is the top light, that is, on the top of the chamber on the light function, but the KENTON instrument does not recommend this way of light, oh, the reason is very simple, because each partition will place objects, so it will lead to the bottom of the object can not be uniform by the light. When we are in choose and buy, ask ourselves to need above all what kind of illumination means, what illumination means that asks the manufacturer to use next. light incubator

Are there any requirements for the environment in which the mold incubator is placed?

Pay attention to the use of mold incubator : 1. Do not use the instrument when the battery indicator indicates that the power is exhausted. If the device is not used for a long time, please remove the battery and store it. 2. Do not store or use the instrument in high temperature, high humidity, inflammable, explosive, and strong electromagnetic field environments. 3, use a wet cloth or detergent to clean the instrument shell, do not use friction or solvent. 4. When the instrument is wet, it should be dried before storage.

Biochemical incubator application: compost extract seed germination rate determination

Biochemical incubators are most common in laboratories. Biochemical incubators are widely used, such as seed germination rate determination of compost extract. The extract of the compost sample was extracted, and the germination rate of seeds was measured. According to the literature, a piece of filter paper was spread in a 9cm petri dish, 20 seeds (radish seeds were used) were placed, and 5ml extract was added (I added 10ml). The seeds were cultured in a biochemical incubator at 25 oC for 5 days. Calculate the formula to calculate the speed germination index can be. The ions were removed as a blank control. Calculation formula: F= (A1×A2) /(B1×B2)×100% F: seed germination index; A1: germination rate of seeds cultured infiltrate of compost samples; A2: Root length of seeds cultured infiltrate of compost sample; B1: germination rate of seeds cultured in deionized water; B2: Root length of seeds cultured in deionized water.

After the vacuum drying oven is heated, can the rubber hose between the vacuum pump and the oven be disconnected?

图片
 It is completely possible to avoid the phenomenon of vacuum pump oil return caused by improper operation. When there is no need to vacuum, you can pull out the linked rubber hose on the oven body. It should be noted that the vacuum degree is not enough in the drying process, and when the drying is ready to vent, it should be linked back to the vacuum pump. Or replace the oil-free vacuum pump, do not need to worry about this problem. Kenton Instrument professional vacuum drying oven manufacturer, its production of vacuum drying oven widely used in biochemistry, chemical pharmaceuticals, medical and health, agricultural research, environmental protection, and other scientific research applications, used for powder drying, baking, sterilization and disinfection, especially suitable for drying heat sensitivity, easy decomposition, easy oxide Quality, and complex ingredients are quickly dried. vacuum drying oven

The function of biochemical incubator is introduced

图片
Biochemical incubator This incubator is equipped with electric wire heating and compressor cooling. Therefore, it can be adapted to a large range, which can be maintained at a constant temperature throughout the year, and thus gradually popularized. The incubator is similar to an electric incubator in use and maintenance. As a result of the installation of a compressor, it is necessary to comply with the refrigerator maintenance precautions, such as maintaining voltage stability, not excessive tilt, timely cleaning of the dust on the radiator. Characteristics: Biochemical incubator generally does not control humidity and does not have an anti-virus function. With double system cold and heat control temperature. Generally with a glass observation window. The biochemical incubator is indispensable laboratory equipment for plant, biology, microorganism, genetics, virus, medicine, environmental protection, and other scientific research and education departments, widely used in low-tempera

The preheating technology and circulating air duct design of the drying oven are explained

The pre-heating technology of the inner liner is to distribute the heating elements evenly in the inner liner to pre-heat the inner wall, then through a heat transfer and fan convection, the more the heating surface is distributed, the better the effect. The circulating air duct is a reasonably designed air transport system combining fan and impeller, air inlet, and outlet, which enables a uniform and constant temperature and humidity in the inner liner. The duct design can be divided into single-sided, double-sided to four-sided circulation convection, the more convection surfaces the better the effect. drying oven:https://en.kentonchina.com/list/Drying-oven.html

Why is the constant temperature and humidity chamber so expensive?

图片
Constant temperature and humidity chamber using balanced heating and cooling technology, for example, in the cooling process to start the refrigeration system, also start the heating system at the same time, through the program to control the proportion of time between the two, the balance of good adjustment of the heating and cooling capacity, so as to achieve the purpose of cooling, the uniformity of fluctuations and small impact, the temperature process is also the same principle, and balanced technology can also effectively solve the evaporator continuous operation due to The same principle applies to the temperature rise process. constant temperature and humidity chamber

What is the difference between the C series and the A and AS series of industrial ovens?

图片
What is the difference between the C series and the A and AS series of industrial ovens ?   The "A" series comes standard with an aluminium housing motor, the "C" series with an iron housing motor (the aluminium housing dissipates heat faster and is more durable than the iron housing). "A" standard with high-temperature silicone door seal, "C" asbestos fibre door seal (silicone door seal is more effective and no contamination) "A" standard with progressive locking hinges and thicker hinges. "C" spring-loaded latch (progressive latch for better sealing) "A" has a thicker construction and steel plate material. "A" is made of high-temperature-resistant heating tubes and electrical components of well-known brands, more durable. The AS is the "A" series with a stainless steel liner. Therefore, in terms of configuration, AS is the highest, A is the second, C is the last, of course, the price is also fro

Constant temperature drying oven replacement observation window glass method

  The observation window is set on the door of the constant  temperature drying oven , which can directly see the changing state of the processed products in the heating process, bringing intuitive effect to the customers' processed products and can achieve better drying effect. However, the glass is sometimes damaged during transportation due to poor logistics protection, or the glass can also be knocked down accidentally during use. When the glass is damaged and needs to be replaced, how should we proceed? We can do it in the following three steps. 1, Remove the door, first remove the entire outer door by removing the hinge screws from the case and lay it flat, noting that the door panel is facing down. Next, remove the door sub-panel and take out the inner glass and glass fixing frame, followed by the outer glass. 2, Install the new outer glass, press on the glass retaining frame, and then install the new inner glass. Cover the door sub-panel and secure it with screws. 3, Assemb

Kenton Instrument patented product:CO2 incubator

图片
  CO2 incubator  is characterized in that the incubator comprises the cabinet and inner chamber; heating wires are distributed on the four walls of the inner chamber, and the heating wires can preheat the inner walls; The bottom of the chamber is provided with a water pan for holding water. The water pan is integrally formed with the chamber. The co2 incubator comprises several shelves for carrying objects, and the shelves are provided holes that are convenient for ventilation; The interior is provided with guide rails for placing the shelf. The incubator also includes an air inlet valve, which has a built-in filtering device. The utility model is provided with an ultraviolet sterilization lamp, and the ultraviolet sterilization lamp is arranged inside. The fan is fixed on the upper inner wall. The glass door is installed between the outer door and the cabinet and provided with a test hole. One side of the outer door is provided with a water-retaining strip for water-retaining, and the

Illumination testing of biosafety cabinets

图片
  Illuminance testing: test according to YY 0569-2011 6.3.4, in the center line of the non-stick tape in the middle of the work surface of the  biosafety cabinet , 150 mm from each of the left and right side walls, each measurement point is no more than 300 mm away. For example, if the distance between the left and right side walls of a cabinet is 1240 mm, after subtracting the distance between the left and right points of 300 mm, the remaining distance is 940 mm. Background illuminance measurement: turn off the lights of the  biological safety cabinet , digital illuminance meter press POWER key, the lower right of the display shows "20", press RANGE key, adjust to the lower right of the display shows "2000", illuminance value in The illuminance value is displayed in "LUX" units. Select the appropriate measuring position and the value shown at the bottom right of the display of the illuminance meter is an indication of the measuring range. Place the light

Observation window airflow test for biosafety cabinets

图片
  Observation window airflow test. a) At a height of 25mm behind the observation screen and 150mm above the top of the front window opening, accumulate the smoke generated by the suction bulb and allow it to move slowly from one end of the biological safety cabinet to the other. b) Observe the direction of the smoke flow and tick the yes or no oven for the phenomenon in the "Description of the observed results" oven of the test record. c) Evaluation of results According to YY 0569-2011 5.4.9.1 "The airflow in the working area of the safety cabinet shall be downward, without vortex or upward airflow and without dead spots. The airflow should not escape from the cabinet." The observations are evaluated in accordance with the requirements of the standard and a satisfactory conclusion is given. Airflow test at the edge of the front window operation opening a) At a distance of approximately 38 mm from the outside of the biosafety cabinet , the smoke from th

What standard biochemical incubator is used for water analysis

 So how to judge whether the biochemical incubator meets the standard? Here from the technical performance talk. Operating temperature: general type: 4~50℃, low-temperature type: -10~+50℃; Temperature fluctuation: +-1℃ (refrigeration operation state), +-0.5℃ (other operating temperature); Temperature uniformity: ≤2.0 (37℃), less than or equal to 3.0 (other working temperature); Cooking time: ≤60min Heating time: ≤60min The above provisions are based on the ambient temperature of 20℃. The biochemical incubator is aimed at constant temperature culture and sample preservation. The requirement of technical performance is the embodiment of ensuring the normal work of a biochemical incubator. It is important to select the product according to the above biochemical incubator criteria. en.kentonchina.com

Anaerobic incubator case: bifidobacterium culture

图片
 Anaerobic incubator case: bifidobacterium culture The culture medium formula of bifidobacterium can refer to the national standard of Microbiology test Methods for food hygiene GB/T4789-2003, which is the latest version in 2003, and the culture and identification of bifidobacterium and lactic acid bacteria are newly added. I have made a culture medium with reference to the NATIONAL standard, but it is not BBL. I am sorry that I can not remember the name at that time. The ingredients in the formula are simpler than BBL, and there is no need to do a tomato extraction solution. In addition, the culture needs at least 72 hours, if the experimental conditions are simple, it is best to use pyrogallic acid and anhydrous sodium carbonate reaction method is better, simple operation, good effect. Focal gallic acid and anhydrous sodium carbonate 2 grams each said (says good in advance, standby), to prepare than to use a dish of AGAR (say good medicine can be put on the above, do not mix), and r