博文

目前显示的是 四月, 2020的博文

How to improve the temperature and humidity uniformity of the blast drying oven

图片
1. Improve the airflow structure of the drying oven : The quality index of the "temperature uniformity" of the drying oven mainly depends on the structure of the airflow. The drying box usually adopts a single air duct structure to organize the airflow, and the airflow mainly comes from the centrifugal fan system. In this structure, the design of the casing of the centrifuge and the design of the wind deflector are the key to determining the index. Therefore, we first redesigned the volute in strict accordance with the Archimedes spiral principle. The airflow of the air outlet of the volute can be evenly blown through the heater to ensure uniform air supply. In addition, the air outlet and air outlet of the air deflector have also been correspondingly improved to increase the air volume of the air inlet as much as possible, while increasing the air pressure and wind speed of the air outlet. The airflow can be evenly circulated in the working room. Second, determine th

What are the factors that affect the incubator price?

图片
Incubator, widely used for BOD determination, water analysis, storage strains, mold, microbial culture, scientific research, temperature test, culture test, environmental test, and so on. The general temperature range in 0℃~65℃, with refrigeration and heating two-way thermostat system, the temperature can be controlled, automatic or manual. There are many factors that affect the price of incubators . Here, Kenton explains some of the most common factors for you. Equipment composition, first of all, temperature control system, pointer, digital or LCD screen, three comparisons, LCD price is the most expensive, the pointer is relatively cheap; Then, whether there is a microcomputer intelligent PID control technology. The better material is imported sus304 stainless steel, followed by stainless steel sus202, and finally galvanized. Choose galvanized sheet relative price will be cheaper. The temperature control range can be selected according to their own needs, but usually, the larger t

How to use constant temperature drying oven?

图片
Constant-temperature drying ovens are actually not common in ordinary life, but they must be familiar with laboratory workers in schools, research institutes, or industries. So do you know how to adjust the temperature of the constant temperature drying oven and how to use it? Instructions How to use constant temperature drying oven? (1) Instructions for operation keys on the panel 1) Display electric meter: display measured temperature; 2) Setting dial: rotate the setting dial to adjust the required temperature value; 3) Greenlight: turn on the power, the green light is on; 4) Red light: when the measured temperature reaches the set value, the red light is on; (2) Instructions for use 1. Before turning on the power, make sure that the switch is set to the "off" position to check whether there is a circuit break or leakage. 2. Since there will be a slight smoking process during the first heating, it is recommended not to put the sample, close the door, u

How to install and use the Laminar flow cabinet?

The  Laminar flow cabinet ( ultra-clean workbench )  is widely used in the electronics, precision machinery industry that mainly controls dust and agriculture, forestry, and medical and health services that mainly control dust, bacteria, and viruses. The installation of the ultra-clean workbench is very important. The installation steps are as follows: 1. The choice of the installation position of the ultra-clean workbench will directly affect the use effect and service life. Therefore, when installing the ultra-clean workbench, it must be installed in a plant with good hygienic conditions. It is best to lay a plastic floor or a water mill floor to facilitate cleaning and dust removal, and pay attention to the sealing of doors and windows to avoid the influence of external dust particles on the interior. Extend service life and ideal purification effect. 2. Open the product packaging, check whether the physical items are consistent with the items listed in the packing list, the

How to remove dust in the drying oven?

图片
The dust on the surface or inside of the drying cabinet is mostly tiny dust particles with a small amount of static electricity, which often floats in the air and moves with the airflow, and it will adhere to the object when it encounters it, and it will be almost impenetrable. Dust attached to the model specimen will affect its color, dust on moving parts will increase wear, dust on electrical appliances, severe cases will cause a short circuit, leakage, valuable dust on precision instruments, serious cases will make the instrument scrapped. drying oven There are many ways to remove dust in the drying oven , which should be determined by the condition of the dust surface and the degree of dust adhesion. In the dry air, if there is less dust or the dust has not been dampened and become a patch, you can use a dry cloth to wipe, towel brush, soft brush and other methods to remove the dust on the general instrument; Blowing and dusting off the ear-washing ball pump can also be us

Drying of utensils in small drying ovens

图片
There are many laboratory instruments and equipment, and large instruments and equipment are valuable. Be aware that these devices are small, but they are more practical and powerful. When the glassware is dried in a small drying oven , first remove the water in the container as much as possible to prevent the water from dripping and causing the oven to be damaged. Then place the mouth down and put it on the lower layer as much as possible to prevent dripping from the upper layer to the lower layer It may cause damage to the vessel. Do not dry flammable and explosive substances in the oven, such as samples containing ethanol, ether, etc. Some ovens are not suitable for use with high humidity. At this time, it is appropriate to choose a drying oven .

Various drying ovens, very complete

图片
GX  electric heating constant temperature oven The first paragraph, DHG constant temperature electric heating oven 1. Precision LCD constant temperature drying oven (Level ★★★★★) Adopt imported fan, mirror stainless steel liner. With microcomputer interface, with timing, timing range 0 ~ 999 minutes. 2. Precision digital display constant temperature drying oven (Level ★★★★ ☆) Intelligent PID control digital display, mirror stainless steel liner. Upgrade the wind design to make the temperature more uniform. With timing, the timing range is 0 ~ 999 minutes. The second paragraph, 101 constant temperature blast drying oven 1. Pointer type electric blast drying oven (galvanized sheet liner) (Level ★★★) 2. Pointer electric blast drying oven (stainless steel liner) (Level ★★★) 3. Digital display electric blast drying oven (galvanized gall bladder) (Level ★★★) 4. Digital display electric blast drying oven (stainless steel liner) (Level ★★★) This series uses

Technical parameters of Illumination incubator

In biological genetic engineering, medical treatment, health and epidemic prevention, drug inspection, agriculture, animal husbandry and aquatic products, a kind of test equipment is often used-the Illumination incubator . The Illumination incubator is a high-precision constant temperature light simulation test equipment with refrigeration, heating, and light intensity control. , Can be used for plant cultivation, breeding test, cultivation, storage of bacteria, mold, microorganism, BOD determination of water analysis and other temperature constant temperature test. technical parameter: 1. Temperature control range: 5 ~ 50 ℃ without light, 10 ~ 50 ℃ with light; 2. Temperature accuracy: ± 0.1 ℃; 3. Tolerance of temperature fluctuation: ± 1 ~ 1.5 ℃ (within 10 ℃ ~ 40 ℃ setting range); 4. Tolerance of temperature uniformity: ± 1 ℃ (150 / 250S), ± 1.5 ℃ (350S) (within 10 ℃ ~ 40 ℃ setting range); 5. Power supply voltage: AC 220V / 50Hz; 6. Input power: 1000W (150L) 1150W (250L) 1400W (350L);

What is the airflow mode of the biological safety cabinet?

图片
The airflow pattern of the biological safety cabinet is quite special. Let me explain in detail below. The fan sucks the ambient air into the air intake grille on the operation table in front of the work area of ​​the biological safety cabinet, to avoid polluting the surface of the work table and user samples, and the entering gas is not mixed with the clean gas in the cavity of the work area. Ambient air enters through the air inlet in front of the work area to avoid contamination by the surface of the work area and the sample. The intake air flow does not mix with the clean gas in the working area of ​​the safety cabinet, passes through the channel, and flows to the air pressure chamber (fan chamber) on the top of the safety cabinet. About 30% of the gas in the air pressure chamber passes through the filter and is discharged into the room. The remaining 70% of the gas passes through the sink air filter and enters the work area, forming a clean vertical air flow to the work surfac

What are the structural characteristics of biological safety cabinets?

The structural characteristics of the A2 biological safety cabinet are as follows: cabinet, frameless glass window, SUS304 stainless steel countertop, front hand rest, built-in waterproof power socket, universal wheel bracket, fan, downflow filter, external exhaust flow It consists of filter, fluorescent lamp, ultraviolet lamp, LCD controller and alarm system. The cabinet body is made of high-quality cold-rolled sheet, processed by laser cutting and a variety of numerical control equipment. The surface is electrostatically sprayed and has a beautiful shape. It conforms to the human body mechanics and the front 10 degree tilt design makes the operation more comfortable.

What should the fruit oven pay attention to?

图片
The fruit oven is a blast intelligent digital display drying oven, which is widely used in fruits, dried fruits, medicinal materials, etc. for drying and baking. But it can not be used for baking food for household food. PV display: display measured temperature, various prompts according to controller status, SV display: display set temperature, various parameters according to controller status; constant temperature time and temperature can be set in the control instrument. Precautions 1. The sample placement should not be too crowded when using the fruit oven , so as not to affect the convection in the box. When placing the oven, please ensure that the oven is effectively grounded to ensure safety. 2. When the temperature rises, please do not splash water on the observation window of the oven door, so as to avoid the glass from bursting due to cold. 3. This drying oven is a non-explosion-proof product. 4. Please do not put volatile, flammable and explosive items into the box fo

What is the difference between the galvanized liner and stainless steel liner in the drying oven?

图片
The drying oven has a galvanized liner and a stainless steel liner. Prices vary, so do you know what is galvanized and what is stainless steel? Galvanizing refers to the surface treatment technology of plating a layer of zinc on the surface of metals, alloys or other materials for aesthetic and rust prevention. The main method used is hot-dip galvanizing. Stainless steel is the abbreviation of stainless acid-resistant steel. It is resistant to weak corrosive media such as air, steam, water or stainless steel. According to your needs, choose the inner tank of different materials.

Does the vacuum drying oven vacuum or heat first?

图片
Many customers encounter a problem after purchasing a vacuum drying oven . Should the vacuum drying oven be evacuated first or heated first? The following Kenton instrument will introduce the correct operation method of the vacuum drying oven: vacuum oven vacuum oven The experimental product is put into the vacuum oven  to evacuate to remove the gas components that can be removed from the material of the workpiece. If the workpiece is heated first, the gas will expand when heated. Due to the tightness of the vacuum oven, the huge pressure generated by the expanding gas may cause the tempered glass of the observation window to burst. This is a potential danger. You can avoid this danger by following the procedure of vacuuming and heating first. If you operate according to the program of heating up and then vacuuming, when the heated air is pumped out by the vacuum pump, the heat will be carried to the vacuum pump, which will cause the temperature of the vacuum pump to rise

Mold incubator with commonly used instruments in microbiology laboratory

图片
The microbiology laboratory is a basic laboratory in the field of biology. For a complete microbiology laboratory, which instruments do we need to configure? Come to Kenton Instrument to explain the mold incubator for you: There are many types of incubators, and its role is to provide a suitable environment for the growth of microorganisms. The biochemical incubator can only control the temperature and can be used as a flat plate culture of general bacteria; the mold incubator can control the temperature and humidity and can be used for the cultivation of molds. It can provide a stable temperature and humidity environment and simulate various climatic conditions. It is especially suitable for samples. Stability testing, long-term experiments, shelf life testing, and cultivation of plants, seeds and microorganisms.

What should I do when the light incubator is not in use?

图片
The light incubator is a constant temperature device with biochemical functions. Usually used for plant germination, nursery, tissue culture, microbial culture, insect, small animal breeding, BOD measurement of water analysis and so on. It is an ideal test equipment for production and scientific research departments in biogenetic engineering, medicine, agriculture, forestry, environmental science, animal husbandry, and aquatic products. Precautions for use    1. After the equipment has landed, if the ground is uneven, it should be leveled.    2. The equipment should be moved in parallel, and the inclination angle in any direction should be less than 45 degrees.    3. During normal operation of the equipment, the contents of the chamber should be placed without affecting the air circulation to ensure uniform temperature and humidity in the chamber.    4. The inner wall of the chamber and the surface of the equipment should be wiped frequently to keep it clean.    5. If the dev