What should be done when vacuum suction appears in vacuum drying oven?

People in the industry know that the vacuum drying oven has the advantages of fast drying speed, small pollution, and no damage to the inner quality of the dried goods. It can be widely used in the food, light industry, chemical industry, and other industries for heating, drying, and constant temperature use. When the vacuum suction phenomenon occurs in a vacuum drying oven , what is the general reason? Vacuum suction phenomenon is caused by the wrong operation when closing the vacuum pump, the valve should be closed first and then the vacuum pump, if the order is opposite, affected by vacuum negative pressure, vacuum pump water or oil will appear suction phenomenon, inexperienced workers may make mistakes. Solutions: A professional to use the vacuum oven. Without experience, you can learn from experience and operate correctly. If it is easy to make mistakes, a check valve should be added between the vacuum pump and the vacuum drying oven. When the vacuum pump stops, the check valve wi

Commercial drying oven:How much tea can be roasted at one time?

According to the professional tea making introduction, generally, about 4 patties can be out of 1 catty of dry finished products, also consider the varieties of tea and weather problems, each kind of tea is different, then calculate how much weight can be roasted at one time according to the number of laminates and load-bearing, and this quantity is the ideal situation, only for reference. commercial drying oven Principle: Through the heat generated by the heating elements, evaporate the moisture in the material to achieve the purpose of dehydration.   Process: The top of the chamber is equipped with electric heat elements and an air fan; when they are working, it is heated by an electric heat element and air circulation through the fan blower to achieve drying effect; the temperature PID control can ensure temperature uniformity.   Scope of application: This product is specially designed for agricultural products such as grain and miscellaneous grains. It is very suitable for dehydrat

How to evacuate the Vacuum drying oven?

图片
 There are many models of Vacuum drying ovens, but the basic structure is similar, generally consisting of three parts: the Vacuum drying oven, electric heating system, and automatic temperature control system. Connect the vacuum pump with the vacuum valve, open the vacuum pump and the vacuum valve in turn, and pump the vacuum. Caution. ①According to the performance of the vacuum pump, the pressure gauge shall be the limit value of the vacuum pump. When the vacuum degree is reached, close the vacuum valve first (if the vacuum valve is not tightly closed, it needs to be replaced in time), and then turn on the power of the vacuum pump. (a) Closure or removal (to prevent back drafting). ③ Observe the vacuum pressure gauge to ensure that the value is stable without significant fluctuations. ④If the vacuum degree is lower than the requirement of dry goods, open the vacuum pump power and vacuum valve again and continue to evacuate. Vacuum pump lifetime. The vacuum drying oven KZ series can

What is the cause of air leakage in vacuum drying oven?

图片
Recently, some customers are asking how to ensure that the vacuum drying oven does not leak after several years. In fact, when the vacuum drying oven leaks after several years of use: Possible causes: When used for a long time, there is air leakage. The biggest possibility is not that the drying oven is broken, but that the sealing parts are damaged and aged. Solutions: Only need to replace the sealing strip, if you still can't solve the problem, that is the valve is damaged, replace some valves. How to ensure that the vacuum drying oven does not leak after several years? Buyers can buy products made by some brand manufacturers. The silicone door seal is formed as a whole to ensure that it will not break due to interface problems after a long time of use. vacuum drying oven

Environmental chamber several experimental sample placement points

图片
Environmental chamber with  many users put in samples due to the result of the experiment is not the standard operation is not accurate, its applicable temperature experiment box up and down to stop the experiment time put on the sample, there is a clear rule under the  Environmental chamber  manufacturer Kenton instrument is summary about how to correctly put sample time for you! 1, liquid test products in the  Environmental chamber  must be filled with the corresponding container, and it is best not to exceed 2/3 of the container, to avoid liquid overflow. 2, chamber   volatile, flammable, and explosive items to stop putting into the experimental box to stop the experiment, conventional equipment has no explosion-proof function. If we must stop such experiments, we must indicate with consumer manufacturers before ordering equipment and request consumer manufacturers to stop some special corrections to the equipment, such as explosion-proof, etc. 3. Rubber experimental products in th

The Control system is the core of the constant temperature and humidity chamber

图片
The Control system is the core of the constant temperature and humidity chamber , it determines the temperature rise rate of the text chamber, precision, and other important indicators. Now the controller of the test chamber mostly adopts PID control, but also a few adopts PID and fuzzy control phase combination control mode. Because the control system of the thermostatic oscillator basically belongs to the category of software, and this part in the use of the process, generally there will be no problems. In the constant temperature and humidity chamber refrigeration principle diagram, we introduced the temperature and humidity chamber refrigeration system several important components of the working path. So how do these components work? The refrigerant is adiabatically compressed to a higher pressure by the compressor, and the work is consumed to raise the exhaust temperature. After that, the refrigerant isothermally exchanges heat with the surrounding medium through the refrigerant c

The difference between Laminar flow cabinet and biosafety cabinet

图片
The differences between the Laminar flow cabinet and biosafety cabinet are mainly as follows: 1, biosafety cabinet is safety equipment widely used in scientific research, teaching, clinical testing, and production in the fields of microbiology, biomedicine, gene recombination, animal experiments, biological products, and so on. It is also the most basic safety protection equipment in the first-class protective barrier of laboratory biosafety. 2, Laminar flow cabinet , designed to protect experimental materials, the air is sucked into the pre-filter through the fan, and filtered into the HEPA filter through the hydrostatic chamber, and the filtered air is sent out in the state of vertical or horizontal airflow, so that the operating area can reach the cleanliness of 100, to ensure the production of environmental cleanliness requirements. Can only protect the sample, not the operator. 3, the biological safety cabinet is a negative pressure purification table, the correct operation of th

Light incubator applications

图片
The light incubator is an upgraded version of the biochemical incubator, with constant temperature functions such as heating and cooling, while adding a controllable light function, simulating the change of illumination at different times of the day and night, using different light intensity, light quality, light-darkness ratio, with temperature and humidity changes to observe the growth of products, is the main equipment for environmental testing in biology, medicine, agriculture and animal husbandry, forestry, environmental science, aquaculture, and other departments. The main equipment, widely used in plant seedling selection and cultivation, monitoring the culture of algae in water bodies, water analysis BOD determination, insect and small animal feeding, cell proliferation preservation, and other tests, can also be used for drug stability tests. In addition, the light incubator is not humidity controlled, need to observe the control of humidity can be purchased artificial climate

Melting wax drying oven

图片
 A constant temperature drying oven can be used for wax melts. Constant temperature drying oven temperature control range in room temperature + 5-250 ° C, this temperature generally covers the melting point of the wax, so, constant temperature drying oven application in a wax melting, is ok. It is also an ideal wax melting tool. To a certain extent, the matching of temperature can be used as part of the function of the wax melting machine. Kenton instrument constant temperature drying oven in scientific research units, professional colleges, industrial and mining enterprises, and other laboratories are suitable for use, for drying, curing, baking, wax melting, disinfection, and so on. 21 years of drying oven manufacturers, quality assurance.

Calibration method of constant temperature and humidity chamber

 Measure the ambient temperature and humidity in the c onstant temperature and humidity chamber , mainly check its temperature and humidity deviation, fluctuation, uniformity, etc. Uniformity refers to the temperature and humidity difference of each test point at a certain time in the working space of constant temperature and humidity box in a stable state; Volatility refers to the speed (or amount of change) of the parameters at the center of the workspace with time; Deviation refers to the deviation between the actual measured high and low values and the standard values at each measuring point in the workspace (the above measurement is carried out under the stable state of the equipment). Under normal circumstances, the temperature uniformity of the constant temperature and humidity chamber is not greater than 2.0℃ under high and low temperatures. The temperature fluctuation of the constant temperature and humidity box is no more than ±0.5℃ at high temperature and no more than ±1.0℃

Installation and debugging of Laminar flow cabinet

图片
 A Laminar flow cabinet is a facility that provides a sterile operating environment for laboratory work to protect experiments from the external environment and at the same time provide some degree of protection to the external environment from contamination and to protect operators. Compared with the simple aseptic cover, the clean table has the advantages of allowing free movement of the operator, easy access to any part of the operating area, and higher integrity. Installation and debugging Plugin the power supply of the Laminar flow cabinet , open it according to the function shown on the control panel, clean the working surface and shell of the purification table carefully before starting up, remove dust on the surface area, and carry out normal operation and use 10 minutes after starting up.