Basic knowledge of high and low temperature test chamber

First, the high and low temperature test chamber should be placed in a place with good ventilation, low humidity, and stable ground. There should be 60 ~ 70cm of maintenance space around.

2. The condenser should be cleaned once every three months. The condenser fan should be regularly inspected and the condenser should be decontaminated and dusted to ensure its good ventilation and heat exchange performance.

3. Cleaning and balance of circulating air blades and condenser fans: Similar to cleaning evaporators, because the working environment of the high and low temperature test chambers is different, many small particles such as dust and other particles will condense on the circulating air blades and condenser fans, which should be performed regularly Cleaning.

4. When working in the high and low temperature test box, the number of door openings should be minimized to reduce the overflow of cold air.

Fifth, the power supply voltage fluctuates greatly. If the power is repeatedly turned off, the use of the high and low temperature test box should be suspended, and the power supply should be turned off to prevent the compressor from being damaged. Do not turn on the compressor immediately after the high and low temperature test box is turned off. Stop the machine for 2-5 minutes before starting it.

Six, insist on taking out the test sample after each test, and wipe the inner wall of the high and low temperature test box to keep the inner box clean.

7. When long-term shutdown is not in use, the high and low temperature test chamber should be powered on regularly and monthly for at least 1 hour.

8. When transporting the high and low temperature test box, please pay attention to the body's inclination cannot exceed 30 °. During the transportation, keep the box vertical. Do not place it upside down or horizontally. Do not hold the doorknob or drag the condenser. To avoid damage.

KENTON Apparatus Ltd.:en.kentonchina.com

评论

此博客中的热门博文

What incubator should I use for fungi?

Laminar flow Cabinet architecture introduction

The Control system is the core of the constant temperature and humidity chamber